Part Number Hot Search : 
LM358 D2412 RB2415 H7808AM 30CTQ080 N60UFD AVAR0046 PSPD25
Product Description
Full Text Search
 

To Download SY10E17106 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Micrel, Inc.
3-BIT 4:1 MULTIPLEXER
SY10E171 SY100E171 SY10E171
SY100E171
FEATURES
s s s s s 725ps max. D to output Extended 100E VEE range of -4.2V to -5.5V Differential outputs Split select architecture Fully compatible with industry standard 10KH, 100K ECL levels s Internal 75K input pulldown resistors s Fully compatible with Motorola MC10E/100E171 s Available in 28-pin PLCC package
DESCRIPTION
The SY10/100E171 offer three 4:1 multiplexers with differential outputs, designed for use in new, highperformance ECL systems. The leading 4-bit multiplexer operation is organized pairwise, with each pair being a 2bit multiplexer. Separate select (SEL1A, SEL1B) controls are provided within each pair. The SEL1A and SEL1B signals control the leading multiplexers, while the SEL2 signal controls the output multiplexer. The three select signals can be used to determine which of the four data inputs will be propagated to the corresponding outputs.
BLOCK DIAGRAM
D0a D0b 2:1 MUX SEL
PIN NAMES
Pin D0x-D2x Function Data Inputs First-stage Select Inputs Second-stage Select Input True Output Inverted Output VCC to Output
D0c D0d
2:1 MUX SEL
2:1 MUX SEL
Q0 Q0
SEL1A, SEL1B SEL2 Q0-Q2 Q0-Q2 VCCO
D1a D1b
2:1 MUX SEL
D1c D1d
2:1 MUX SEL
2:1 MUX SEL
Q1 Q1
D2a D2b
2:1 MUX SEL
D2c D2d SEL1A SEL1B SEL2
2:1 MUX SEL
2:1 MUX SEL
Q2 Q2
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
Rev.: E
Amendment: /0
1
Issue Date: March 2006
Micrel, Inc.
SY10E171 SY100E171
PACKAGE/ORDERING INFORMATION
VCCO
Ordering Information(1)
Part Number Package Type J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 J28-1 Operating Range Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Package Marking SY10E171JC SY10E171JC SY100E171JC SY100E171JC SY10E171JZ with Pb-Free bar-line indicator SY10E171JZ with Pb-Free bar-line indicator SY100E171JZ with Pb-Free bar-line indicator SY100E171JZ with Pb-Free bar-line indicator Lead Finish Sn-Pb Sn-Pb Sn-Pb Sn-Pb Matte-Sn Matte-Sn Matte-Sn Matte-Sn
D1b D1a
25 24 23 22 21 20 19
D2d D2c
D2b D2a
SEL1A SEL1B SEL2 VEE NC NC D1c
26 27 28 1 2 3 4 5 6 7 8 9 10 11
18 17 16
Q2 Q2 VCC Q1 Q1 VCCO Q0
SY10E171JC SY10E171JCTR(2) SY100E171JC SY100E171JCTR(2) SY10E171JZ(3) SY10E171JZTR(2, 3) SY100E171JZ(3) SY100E171JZTR(2, 3)
TOP VIEW PLCC J28-1
15 14 13 12
D1d D0a
D0b
28-Pin PLCC (J28-1)
Notes:
D0c D0d VCCO
Q0
1. Contact factory for die availability. Dice are guaranteed at TA = 25C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs.
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E171 SY100E171
TRUTH TABLE
Pin SEL2 SEL1A SEL1B State H H H Operation Output c/d data Input d data Input b data
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0C Symbol IIH IEE Parameter Input HIGH Current Power Supply Current 10E 100E -- -- 56 56 67 67 -- -- 56 56 67 67 -- -- 56 65 67 77 TA = +25C TA = +85C Max. 150 Unit A mA Condition -- -- Min. Typ. Max. Min. Typ. -- -- 150 -- -- Max. Min. Typ. 150 -- --
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0C Symbol tPD Parameter Propagation Delay to Output D SEL1 SEL2 Within-Device Skew Dnm, Dnm to Qn Da, Db, Dc, Dd to Q Rise/Fall Time 20% to 80% TA = +25C TA = +85C Max. 650 850 700 ps -- -- 300 60 40 475 -- -- 650 -- -- 300 60 40 475 -- -- 650 -- -- 300 60 40 475 -- -- 650 ps -- 1 Unit ps 275 450 350 480 650 550 650 850 700 275 450 350 480 650 550 650 850 700 275 450 350 480 650 550 Condition --
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
tskew
tr tf
Note: 1. Within-device skew is defined as identical transitions on similar paths through a device; n = 0, 1, 2 m = a, b, c, d.
M9999-032006 hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10E171 SY100E171
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. (c) 2006 Micrel, Incorporated. M9999-032006 hbwhelp@micrel.com or (408) 955-1690
4


▲Up To Search▲   

 
Price & Availability of SY10E17106

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X